COMMERCIAL GLAZED
STEEL SCREENS.
Interior steel and glass screens. E/EW classification up to 60. Fixed screens to E 120. Premium commercial lobbies, glazed atria, open-plan compartmentation.
Presto is tested and classified to E and EW only — never EI. E controls integrity and flame passage; EW adds limited radiation control. Do not specify Presto where EI (integrity + insulation) is required — use Fuego Light instead.
DFM fabricates the Forster Presto system under annual-audit licence from Forster AG (Switzerland). Forster AG holds all test evidence, Declarations of Performance, and CE certification for this system.
The slim-sightline commercial system.
Presto is Forster's thinnest-profile steel screen system — built for the architectural restraint of commercial lobbies, atria, and open-plan compartmentation where a clean sightline matters as much as the classification.
E controls flame and gas passage. EW adds limited radiation control. Neither provides insulation — the unexposed face will heat up in a fire. If insulation on the unexposed face is required, specify Fuego Light (EI).
Swing Doors
Single and double leaf swing doors in Presto profile. For commercial lobby access, corridor separation, and glazed partitioning where E/EW integrity is the specified requirement.
| Product | Configuration | Classification (E/EW) | Smoke |
|---|---|---|---|
| Presto SW E 30 | Single / double leaf | E 30 | RS / S200 (opt.) |
| Presto SW EW 30 | Single / double leaf | EW 30 | RS / S200 (opt.) |
| Presto SW E 60 | Single / double leaf | E 60 | RS / S200 (opt.) |
| Presto SW EW 60 | Single / double leaf · Max | EW 60 | RS / S200 (opt.) |
Presto swing doors are classified to a maximum of E 60 / EW 60. Presto is never EI rated — if insulation on the unexposed face is required, specify Fuego Light.
Fixed Screens
Non-opening Presto screens. The only Presto configuration that achieves E 120.
| Product | Configuration | Classification (E/EW) | Smoke |
|---|---|---|---|
| Presto FS E 30 | Fixed screen | E 30 | RS / S200 (opt.) |
| Presto FS EW 30 | Fixed screen | EW 30 | RS / S200 (opt.) |
| Presto FS E 60 | Fixed screen | E 60 | RS / S200 (opt.) |
| Presto FS EW 60 | Fixed screen | EW 60 | RS / S200 (opt.) |
| Presto FS E 120 | Fixed screen · Flagship | E 120 | RS / S200 (opt.) |
E 120 in Presto is achieved on fixed screens only. Do not specify E 120 on any swing-door configuration. Presto remains E/EW rated across all configurations — never EI.
Smoke Control Screens
Presto screens configured for smoke control rather than fire integrity. Used for smoke compartmentation in atria, stairwells, and open-plan office floorplates.
| Product | Configuration | Smoke Classification | Leakage (S200) |
|---|---|---|---|
| Presto SC RS | Smoke control screen | RS | Tested at 200 °C |
| Presto SC S200 | Smoke control screen | S200 | Tested at 200 °C |
Smoke classifications (RS / S200) are independent of fire integrity. Where both are required, specify a Presto E/EW configuration with the RS/S200 smoke option selected.
Presto system parameters.
Profile dimensions, glazing build-up, and ironmongery confirmed per project against the Forster Presto system manual. Presto delivers E/EW integrity — not EI insulation.
- Classification
- E 30 / E 60 / EW 30 / EW 60 · E 120 on fixed screens only · RS / S200 smoke
- Profile construction
- Forster Presto welded steel profile · slim sightline optimised for commercial architecture
- Face width
- 50 mm face · thinnest in the Forster range
- Glazing
- E/EW-rated fire glass per Forster specification · thinner build-up than Fuego Light
- Maximum leaf / screen
- Per Forster field-of-application · confirm dimensions per project
- Ironmongery
- Forster-approved hinges, closers, and mortice locks · commercial-grade access control integration
- Smoke control
- RS / S200 smoke seal option · selected independently of E/EW classification
- Acoustic (Rw)
- Up to 38 dB · dependent on glazing build-up
- Application
- Interior only · commercial lobbies, atria, open-plan compartmentation
- Finish
- Powder coat, full RAL palette · anodised finishes available via Forster
Glazing and frame integration.
Presto is installed per the Forster system manual. Glass is supplied and glazed to the Forster specification — the E/EW classification depends on the correct glass, gasket, and seal build-up being delivered together. Substituting any component voids the classification.
Supported substrates: masonry, concrete, structural steel, and engineered timber. Presto is an interior-only system. Smoke-seal engagement must be verified at commissioning where the RS/S200 option has been specified.
Download installation manual →-
01
Verify the opening
Check structural opening against the Forster system field of application and the project-specific fabrication schedule.
-
02
Frame installation
Install Forster profile frame with approved anchors. Plumb, square, and packed to Forster tolerance. Maintain thermal break continuity on Unico.
-
03
Glazing
Glaze with the specified Forster fire glass, gaskets, and intumescent seals. No substitution. Handle per Forster manual to avoid edge damage.
-
04
Commission and record
Test operation, verify smoke seal engagement, and record the Forster DoP reference and installer sign-off for the project file.
Evidence pack — Presto.
Test evidence, Declarations of Performance, and CE certification for Presto are issued by Forster AG. DFM supplies the relevant documents on order confirmation.
ETA & CE Certification
Forster AG European Technical Assessments and CE certification for Presto.
Download PDFs → DoPDeclaration of Performance
Issued by Forster AG per configuration. Supplied on order confirmation with the fabrication schedule.
Request DoP → DatasheetPresto Technical Data Sheet
Swing doors, fixed screens, and smoke control. Profile, glazing, and E/EW classification detail.
Download PDF → DatasheetPresto Smoke Control Data Sheet
RS / S200 smoke classification detail, seal integration, and configuration options.
Download PDF → InstallForster System Manual
Frame fixing, glazing build-up, gasket and seal integration, and field-of-application rules.
Download PDF → NBSNBS Spec Clauses
Pre-written NBS clauses for Presto — E/EW classifications, glazing, and ironmongery references.
Open NBS creator →Presto CE certification is held by Forster AG (Switzerland). DFM fabricates Presto under annual-audit licence and supplies Forster-issued test evidence, Declarations of Performance, and CE documentation with each order.
Presto is classified to E and EW only — never EI. Specify Presto where integrity and flame passage (E) or limited radiation control (EW) is the requirement. Where insulation on the unexposed face is required, specify Fuego Light (EI).
Talk to the UK office →Also in the steel range.
Glazed Fire Doors
EI 30–120 · Side-hung · Fixed · Sliding
Steel and glass fire systems with EI classification. For specifications that require insulation as well as integrity.
View range → DS RangeFire Rated Steel Doors
EI2 30 · 60 · 90 · 120 · Sa4/S200
Single and double leaf. Maximum EI2 120 classification. Standard catalogue.
View range → SG RangeSliding Gates
EI 60 · EI 90 · Sa4/S200 · Wicket option
Single and double leaf fire resistant sliding gates for large-span openings.
View range →Rammy is coming soon. AI-powered technical guidance, product selection, specification support, and CPD bookings — launching later in 2026.