FIRE RATED
STEEL DOORS.
EN 13501-2 classified. EI2 30 to EI2 120. Sa4/S200 smoke control. CE marked under ETA-22/0324. Standard catalogue — no bespoke lead-time premium.
DS Range — EN 13501-2 Classifications
Source: ETA-22/0324 (revised May 2024, OiB Vienna, Notified Body 1322). Each doorset is issued with its own Declaration of Performance.
| Product | Configuration | Fire Classification | Smoke Classification |
|---|---|---|---|
| DS 30-1 | Single leaf | EI2 30 | Sa4 / S200 |
| DS 30-2 | Double leaf | EI2 30 | Sa4 / S200 |
| DS 60-1 | Single leaf | EI2 60 | Sa4 / S200 |
| DS 60-2 | Double leaf | EI2 60 | Sa4 / S200 |
| DS 90-1 | Single leaf | EI2 90 | Sa / S200 |
| DS 120-1S | Single leaf · Flagship | EI2 120 | Sa4 / S200 |
| DS 120-2S | Double leaf · Flagship | EI2 120 | Sa4 / S200 |
EI2 120 is available on single and double leaf as standard catalogue — not a bespoke configuration. Smoke classification Sa4/S200 applies across the range with the exception of DS 90, which is classified Sa/S200.
Doorset parameters.
Standard range parameters from ETA-22/0324. Bespoke dimensions, finishes, and ironmongery specifications on request.
- Leaf construction
- Double-skinned galvanised steel, 1.0–1.5mm faces, mineral-wool core
- Leaf thickness
- 64 mm (DS 30 / 60) · 72 mm (DS 90 / 120)
- Frame
- Galvanised steel profile, factory-welded mitred corners
- Standard dimensions
- Single: 625–1250 × 1875–2500 mm · Double: 1250–2500 × 1875–2500 mm
- Acoustic (Rw)
- 32–42 dB, dependent on configuration
- Hinges
- 3 × heavy-duty steel hinges (single), 6 × (double)
- Lock
- Mortice lock, multipoint option, cylinder to client profile
- Door closer
- Overhead cam-action closer, EN 1154 compliant
- Glazing option
- Vision panel to EI2 rating · max 480 × 880 mm
- Finish
- Powder coat, full RAL palette · Corrosion class C3 (C5 optional)
Gap-fill and frame guidance.
Installation is part of the classification. A DS doorset is only fire rated when installed within the conditions set out in the ETA. Full installation manuals, field-of-application rules, and gap-fill details are provided per doorset on delivery.
Supported substrates: masonry, concrete, steel stud partitions, and timber stud partitions — subject to the field of application noted in ETA-22/0324. Intumescent and smoke-control seals are factory-fitted and must not be removed or painted over.
Download installation manual →-
01
Verify the opening
Check structural opening against the dimensions and substrate noted on the order acknowledgement and ETA field of application.
-
02
Frame fixing
Fix frame with approved anchors at centres specified in the installation manual. Plumb, square, and packed to manufacturer tolerance.
-
03
Gap-fill
Fill the perimeter gap per the ETA field of application. DS 30 / 60 / 90 accept specified intumescent mortar or mineral-wool products. DS 120 requires cement mortar or lime-cement mortar only — mineral wool is not approved. No foam. No generic sealants.
-
04
Commission and record
Hang leaf, test closing and latching, record DoP reference and installer sign-off for the Golden Thread file.
Evidence pack for the DS range.
Every document needed for specification, Gateway submission, and post-occupation record. Versioned and dated for the Golden Thread.
ETA-22/0324
European Technical Assessment. OiB Vienna (NB 1322). Revised May 2024.
Download PDF → DoPDeclaration of Performance
Per doorset. Issued on order confirmation. CE classification and essential characteristics.
Request DoP → DatasheetDS Range Technical Data Sheet
Full product parameters, classifications, and configuration options for DS 30 through DS 120.
Download PDF → InstallInstallation Manual
Frame fixing, gap-fill, ironmongery, and field-of-application rules.
Download PDF → NBSNBS Spec Clauses
Pre-written NBS clauses for the DS range — classifications, smoke ratings, ironmongery references.
Open NBS creator → EvidenceTest Reports
EN 1634-1 test reports from ITB, Efectis, KIWA, OiB, and RISE. Available on request.
Request reports →DFM DS doorsets are CE marked for internal applications under ETA-22/0324, issued by OiB Vienna (Notified Body 1322).
For external door applications, contact us to discuss current certification status before specifying.
Talk to the UK office →Also in the steel range.
Security + Fire
RC3 + EI1 30 / EI2 60
Burglar resistance to EN 1627 combined with fire resistance. One door, one paperwork set.
View range → OS RangeOversized Doors
EI 60 · Non-fire option · CE marked
Non-standard dimensions. Warehousing, logistics, plant rooms, data centres.
View range → DS 00Non-Fire Resistant
Ud 1.2 · Rw 36 dB · C3 corrosion
Steel doors without fire rating. Internal and external. Full RAL palette.
View range →Rammy is coming soon. AI-powered technical guidance, product selection, specification support, and CPD bookings — launching later in 2026.