NON-FIRE
RESISTANT
STEEL DOORS.
Steel doors without fire rating. Internal and external applications. CE marked for external use. Mechanical resistance class 3/4. Full powder coat RAL palette.
DS 00 — Certified Performance
DS 00 is not fire rated. The performance characteristics below are the certified values issued on the Declaration of Performance for external variants under ETA-22/0324.
| Parameter | Standard | Value | Test Reference |
|---|---|---|---|
| Thermal transmittance | Ud — full door | 1.2 W/m²K | EN ISO 12567-1 |
| Acoustic insulation | Rw — full door | 36 dB | EN ISO 10140 |
| Corrosion class | Powder coat system | C3 standard · C5 optional | EN ISO 12944 |
| Mechanical durability | Operating cycles | Class 6 (200,000 cycles) | EN 12400 |
| Mechanical resistance | Strength of doorset | Class 3/4 | EN 1192 |
DS 00 is not fire rated. For fire-resistant steel doorsets see the DS range (EI2 30 – EI2 120). For security-rated variants see DS RC3.
- Internal circulation
- Back-of-house
- Plant rooms (non-rated)
- External entrances
- Secondary access
Doorset parameters.
DS 00 variants for internal and external applications. Bespoke dimensions, finishes, and ironmongery specifications on request.
- Leaf construction
- Galvanised steel faces, 1.0–1.5mm. Single-skinned (internal) or double-skinned with mineral-wool core (external)
- Leaf thickness
- 46 mm (internal, single-skinned) · 64 mm (external, double-skinned)
- Frame
- Galvanised steel profile, factory-welded mitred corners · weather-sealed frame on external variants
- Standard dimensions
- Single: 625–1250 × 1875–2500 mm · Double: 1250–2500 × 1875–2500 mm
- Thermal (Ud)
- 1.2 W/m²K (external variant, full door)
- Hinges
- 3 × steel hinges (single), 6 × (double) · stainless on C5 corrosion spec
- Lock
- Mortice lock, cylinder to client profile · multipoint option
- Door closer
- Overhead closer optional · EN 1154 compliant when specified
- Glazing option
- Vision panel · max 480 × 880 mm · single or double glazed
- Finish
- Powder coat, full RAL palette · Corrosion class C3 standard, C5 optional for coastal / industrial environments
Frame fixing and weather-sealing.
DS 00 doorsets are straightforward to install into prepared openings. Full installation manuals and fixing schedules are supplied per doorset. External variants require correct weather-sealing and threshold detail to achieve the certified Ud value.
Supported substrates: masonry, concrete, steel stud partitions, and timber stud partitions. Anchor pattern per the installation manual. C5 corrosion-class doorsets require stainless fixings and compatible sealants.
Download installation manual →-
01
Verify the opening
Check structural opening against the dimensions and substrate noted on the order acknowledgement and ETA field of application.
-
02
Frame fixing
Fix frame with approved anchors at centres specified in the installation manual. Plumb, square, and packed to manufacturer tolerance.
-
03
Weather-sealing (external)
Apply perimeter sealant and threshold compound per manual. Required to achieve certified Ud and C3/C5 corrosion performance.
-
04
Commission and record
Hang leaf, test closing and latching, record DoP reference (external variants) and installer sign-off for the project file.
Evidence pack for DS 00.
Performance data, DoPs (external variants), and installation documents. Note DS 00 is not fire rated — no EN 13501-2 classification applies.
ETA-22/0324
European Technical Assessment. OiB Vienna (NB 1322). Revised May 2024.
Download PDF → DoPDeclaration of Performance
For external DS 00 variants under ETA-22/0324. Thermal, acoustic, and mechanical characteristics.
Request DoP → DatasheetDS 00 Technical Data Sheet
Full product parameters, dimensions, and ironmongery schedule for internal and external DS 00 variants.
Download PDF → InstallInstallation Manual
Frame fixing, gap-fill, ironmongery, and field-of-application rules.
Download PDF → NBSNBS Spec Clauses
Pre-written NBS clauses for the DS range — classifications, smoke ratings, ironmongery references.
Open NBS creator → EvidenceTest Reports
Thermal, acoustic, corrosion, and durability test reports per EN ISO 12567, EN ISO 10140, EN ISO 12944, and EN 12400.
Request reports →DS 00 external variants carry CE marking under ETA-22/0324, issued by OiB Vienna (Notified Body 1322), covering thermal, acoustic, mechanical, and corrosion performance declared on the DoP.
For UK external door applications, contact us to confirm current certification status before specifying. Internal DS 00 variants are supplied without fire certification — they are not fire doors.
Talk to the UK office →Also in the steel range.
Security + Fire
RC3 + EI1 30 / EI2 60
Burglar resistance to EN 1627 combined with fire resistance. One door, one paperwork set.
View range → OS RangeOversized Doors
EI 60 · Non-fire option · CE marked
Non-standard dimensions. Warehousing, logistics, plant rooms, data centres.
View range → DS RangeFire Rated Steel Doors
EI2 30 · 60 · 90 · 120 · Sa4/S200
Single and double leaf. Maximum EI2 120 classification. Standard catalogue.
View range →Rammy is coming soon. AI-powered technical guidance, product selection, specification support, and CPD bookings — launching later in 2026.
Coming Soon